Data Connectivity
GENESIS V11 - MELSOFT Connection with MX Controller
Detailed description how to configure connection between GENESIS V11 and MX Controller using MELSOFT Connection. The controller model used in this example was MXF100-16-P32. Connection to MX Controller was introduced in GENESIS version 11.05 and will ...
DIGITAL - GENESIS Accessing Genesis Data via API
Podsumowanie: Artykuł opisuje, jak odczytywać dane z systemu Genesis za pomocą API. Przykłady zostały wykonane w środowisku testowym Postman. Proces konfiguracji obejmuje zarówno ustawienia systemu Genesis, jak i konfigurację certyfikatów serwera. ...
GENESIS V11 - MQTT connection to iQ-F PLC (FX5-ENET)
This article explains how to read data from an iQ-F series FX5-ENET module to GENESIS V11 using a dedicated decoder. A sample GX Works3 project used in this example is added as an attachment. Precautions The MQTT communication function is officially ...
GENESIS - MQTT Connection (Publish/Subscribe)
The article describes how to configure data exchange using the MQTT protocol with the GENESIS software. It presents the configuration for both the publisher and the subscriber. For testing purposes, the RD55UP12-V intelligent module and the MQTT ...
Iconics Genesis V11 - MELFA connection + Asset Builder - gathering data from an iQ-R integrated robot (R16RTCPU)
This article shows how to directly connect Genesis V11 with MELFA robots running on iQ-R integrated R16RTCPU controllers. It also describes how to automatically generate assets and displays with robot data using the Asset Builder. Robot configuration ...
Iconics Genesis V11 - FREQROL connection + Asset Builder - gathering data from an inverter
This article shows how to directly connect Genesis V11 with FREQROL frequency inverters. It also describes how to automatically generate assets and displays with inverter data using the Asset Builder. Supported inverters: FR-A800-E FR-E800-E ...
Iconics Genesis V11 - MELFA connection + Asset Builder - gathering data from a standalone robot (CR800-D controller)
This article shows how to directly connect Genesis V11 with MELFA robots running on standalone CR800-D controllers. It also describes how to automatically generate assets and displays with robot data using the Asset Builder. Robot configuration Using ...
Iconics Suite - SNMP Connection with eWon
Summary: this document describes how to connect with eWon router using SNMP Connection MIB file for SMNP connection to eWon you can find on HMS website ...
Iconics Suite - Database connection
Summary: This article describes how to integrate ICONICS software with various relational database systems, using SQL Server as an example. It covers the basics of connecting to databases and performing SQL queries such as SELECT, INSERT, UPDATE, and ...
Iconics Suite - Dynamic tag - Always on scan / Scan rate option explanation
This article explains when and how to use "Always on scan" option for Dynamic Tag What's Always On Scan option for? You can configure the Dynamic tag with option Always on scan. If the Always on scan option is checked then the interval of ...
Iconics Suite - Melsoft connection with iQ-R
Detailed description how to configure connection between Iconics Suite SCADA and iQ-R PLC controller using Melsoft Connection Remember that your PC has to have the static IP address in the same subnet as PLC. iQ-R PLC default address is 192.168.3.39 ...
Iconics Suite - Melsoft connection with FX5
Detailed description how to configure connection between Iconics Suite SCADA and iQ-R PLC controller using Melsoft Connection Remember that your PC has to have the static IP address in the same subnet as PLC. FX5 PLC default address is 192.168.3.250 ...
Iconics Suite - MODBUS connection with FX5
Detailed description how to configure connection between Iconics Suite SCADA and FX5 plc controller via MODBUS. FX5 side configuration Open Your FX5 project in GX Works3 to add new MODBUS connection. Go to the Navigation tree -> Parameter -> FX5UCPU ...